Bando 828XL075G XL Timing Belt LIGHTING BLOCKSBando 828XL075G The extra durable, highly flexible neoprene backing provides excellent abrasion and wear resistance especially important if power is transmitted from the back of the belt. Backing also guards the tensile cords against oil, grease, dirt, and moisture. Continuous, helically wound high strength fiberglass tensile cords guarantee dimensional stability to eliminate take up adjustments. Heavy torque loads wont fatigue this super strong cord.
Efficiency32 %
7 FULL LOAD AMPS PRIMARY 23
5 POLES 4 NUMBER SPEEDS 1 RPM 1740 HERTZ 60 VOLTS PRIMARY 230 VOLTS 230 FRME 215 SHAFT CODE T ASSEMBLY POSITION F-1 MOTOR TYPE SM OPPOSITE END BEARING 6205-2Z/J/C3 SHAFT END BEARING 6208-2Z-J/C3 AMBIENT 40 SERVICE FACTOR 1 STARTCAPMFD N\A SHIPPING WEIGHT 148 INSULATION CLASS F KVA CODE LETTER G NEMA NOMINAL EFFICIENCY 83
4 NEMA NOMINAL EFFICIENCY 91 FULL LOAD AMPS PRIMARY 35/17
0 a Front Face Code Standard Front Shaft Indicator None Heater Indicator No Heater Insulation Class F Inverter Code Inverter Duty KVA Code H Lifting Lugs Standard Lifting Lugs Locked Bearing Indicator Locked Bearing Max Speed 5400 rpm Motor Lead Exit Ko Box Motor Lead Termination Flying Leads Motor Lead Quantity/Wire Size 3 @ 14 AWG Motor Type 0742M Mounting Arrangement F1 Number of Poles 2 Overall Length 21
NidecA55CGD-9658
Bando - 6-11MS2120 Ideally suited for short center distances and small diameter pulleys
UL approval UL489 Trip curve C Number of poles 3 poles Rated current 5 A Maximum voltage 277/480 VAC / 125 VDC Type Thermal-magnetic Attributes
5 a Front Face Code Standard Front Shaft Indicator None Heater Indicator No Heater Insulation Class B Inverter Code Inverter Ready KVA Code M Lifting Lugs No Lifting Lugs Locked Bearing Indicator Locked Bearing Motor Lead Exit Ko Box Motor Lead Termination Flying Leads Motor Lead Quantity/Wire Size 9 @ 18 AWG Motor Type 3526M Mounting Arrangement F1 Number of Poles 2 Overall Length 13
7 a Front Face Code Standard Front Shaft Indicator None Heater Indicator No Heater Insulation Class F Inverter Code Inverter Ready KVA Code K Lifting Lugs Standard Lifting Lugs Locked Bearing Indicator No Locked Bearing Max Speed 1800 rpm Motor Lead Exit Ko Box Motor Lead Termination Flying Leads Motor Lead Quantity/Wire Size 9 @ 18 AWG Motor Type 0526M Mounting Arrangement F1 Number of Poles 6 Overall Length 12
5 kW (2 HP) Number of Poles 4 Frequency 60 Hz Rated speed 1735 rpm Slip 3
Load 57° C Start Configuration DOL Break-Down Torque 174 LB-FT Pull-Up Torque 119 LB-FT Locked-Rotor Torque 139 LB-FT Starting Current 892 A Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S